North Penn Business Park,
4500 North Cannon Ave. Lansdale, PA
19446, USA
Tel No.: (267) 436-3991
Fax: (215) 362-5343
CRAIG MILLS:
Email id: cmills@apantec.com
Tel No.:267-436-4034
|
|
|
 |
|
 |
|
|
 |
|
 |
|
 |
 |
Monday, March 15, 2010 |
| Apantec Partners with Fuji |
| More |
|
 |
Monday, November 24, 2008 |
| Shin-Kori 3 & 4 complete RMS system award! |
| More |
|
|
|
 |
|
 |
|
|
|
| [-- BACK
to Products --] |
| GI1 Ion Chamber Detector |
| The GI1
Ion Chamber detector is a sealed ion chamber
probe packaged in a cylindrical aluminum enclosure
and fitted with a multi-pin circular connector
for interconnection to an Apantec
RM1 series display unit. The GI1
is used on area monitoring applications with transient
or burst radiation levels, or those channels with
anticipated high activity such as containment
/ post accident detection. |
The GI1
includes a current-to-frequency converter for
converting the current output signal from the
ion chamber sensor into pulses suitable for counting
by the RM1 series display unit input circuitry.
The RM1 display and control unit provides Ethernet
and serial RS485 communications for networking
to a central computer using the Apantec
DORIS software. |
| The GI1 measures a range of
100 uR/hr to 100 R/hr. |
| The GI1 is
also available with an internal isotopic check source.
These instruments are designated as the models GI1C. |
| For high range and high TID applications, please
refer to the Apantec model CIC100 Ion Chamber detector
design. |
|
|
Detector Type: |
Ion chamber, sealed |
|
Range: |
100 uR/hr to 100 R/hr |
|
Energy Response: |
±20% from 80 keV to 2.5 MeV Referenced
to 137Cs |
|
Saturation: |
will not saturate in fields up to 1,000
R/hr |
|
Accuracy: |
±20% over entire range |
|
Environment: |
14°F to 122°F
(-10°C to 50°C)
0-95% RH |
| Operating
Voltage: |
+12 VDC Biasing voltages internally generated |
| Dimensions: |
12.5 in. (317.5 mm) L x
2.5 in. (63.5 mm) dia. |
| Weight:
|
3 lb (1.35 kg) nominal |
| Note:
The GI1 and ID100C are also available with
SI Units of measurement (Sv/hr(H*10) |
|
| [-- BACK
to Products --] |
|
|
| © 2009; Apantec,LLC. All Rights Reserved. |
|
|